Baxi boiler fault codes explained
Type the code on your Baxi boiler’s display to see what it means, what you can safely try yourself, and when to call a Gas Safe engineer.
Safety first
- Smell gas? Don’t touch switches, open windows, turn off the gas at the meter and call the National Gas Emergency Service on 0800 111 999 straight away.
- Never remove the boiler casing. Everything inside must only be worked on by a Gas Safe registered engineer.
- Only try the simple checks on this page. If a code comes back after one reset, stop and get an engineer out – resetting it again and again can cause more damage.
Quick checks before you callPressure · gas · frozen pipe · reset
Low pressure
Most boilers need 1–1.5 bar when cold. If it’s below 1 bar, top it up with the filling loop or filling link under the boiler. Baxi’s guide
Gas supply
Check the hob works and, if you have a prepayment meter, that it has credit.
Frozen condensate pipe
In freezing weather, warm the plastic condensate pipe where it runs outside with a hot water bottle or warm (not boiling) water from a watering can, then restart the boiler. Baxi’s guide
Reset – once
Press the reset button (or turn the selector to R and hold for 5 seconds on older models). If a spanner symbol shows, you can’t reset it yourself. Baxi’s guide
Showing all 69 codes.
Codes like E118, E133, E160
Baxi Duo-tec, Platinum, EcoBlue, Assure, Megaflo System, 600 & 800 (first generation). On some displays a three-digit code flashes in two parts – E133 shows as “E1” then “33”.
-
E09
Gas valve connection fault.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E10
Outdoor (external) temperature sensor fault.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Book an engineer to check the outdoor sensor and its wiring. Book an engineer →
Source: Boiler error codes
-
E12 / E13
Water flow switch fault (stuck open or stuck closed).
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
E15
Gas valve fault.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E20
Central heating temperature sensor fault.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi Duo-tec Combi user guide (47-075-96) · Baxi 600 Combi user guide (47-077-28)
-
E28
Flue temperature sensor fault.
What you can try
- In freezing weather this code can also mean the condensate pipe is frozen – thaw it first (see “Quick checks” above).
- Otherwise, write the code down – it’s a part inside the boiler.
When to call a Gas Safe engineer
If it’s not frozen weather, or the code is still showing after thawing the pipe and a reset. Book an engineer →
Source: Boiler error codes · Baxi Duo-tec Combi user guide (47-075-96) · Baxi 600 Combi user guide (47-077-28) · What do error codes E28, E53, E133, E119 or E128 mean?
-
E40
Central heating return temperature sensor fault.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E50
Hot water temperature sensor fault.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi Duo-tec Combi user guide (47-075-96)
-
E83 / E84 / E85 / E86 / E87
Communication fault between parts of the boiler’s controls.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E103 / E104 / E107
Safety Assist fault (battery exhausted, faulty Safety Assist board, or boards not synchronised).
What you can try
- Nothing to fix yourself.
- Write down the code.
When to call a Gas Safe engineer
Baxi says to contact your installer, service engineer or Baxi Customer Support. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E109
Pre-circulation fault – the boiler can’t confirm water is circulating before it fires.
What you can try
- Check the pressure is about 1–1.5 bar and top it up if it’s low.
- Otherwise there’s nothing to fix yourself.
When to call a Gas Safe engineer
If the pressure is fine and the code is still showing – the pump, valves or system water need checking. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E110
Overheat – the safety thermostat has operated (often a jammed pump or air in the system).
What you can try
- Reset the boiler once (on Duo-tec models, turn the selector to Reset and hold for at least 5 seconds).
- Don’t keep resetting it if it comes straight back.
When to call a Gas Safe engineer
If the boiler doesn’t relight, or the code shows regularly – there may be a circulation problem (pump, air or sludge). Book an engineer →
Source: Boiler error codes · Baxi Duo-tec Combi user guide (47-075-96) · Baxi 600 Combi user guide (47-077-28)
-
E118
Water pressure too low (below 0.5 bar).
What you can try
- Look at the pressure gauge or display. If it reads below 1 bar, top it up to about 1–1.5 bar using the filling loop or filling link under the boiler, then close it again.
- Then reset the boiler if the code doesn’t clear on its own.
When to call a Gas Safe engineer
If you need to top up more than every few weeks, the pressure won’t hold, or you can see water leaking – it may be a leak, the expansion vessel or the pressure relief valve. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28) · Why is my boiler pressure low?
-
E119
Water pressure too low (below 0.5 bar) – shown on Duo-tec and Platinum models.
What you can try
- Look at the pressure gauge or display. If it reads below 1 bar, top it up to about 1–1.5 bar using the filling loop or filling link under the boiler, then close it again.
- Then reset the boiler if the code doesn’t clear on its own.
- In freezing weather this code can also mean the condensate pipe is frozen – thaw it first (see “Quick checks” above).
When to call a Gas Safe engineer
If you need to top up more than every few weeks, the pressure won’t hold, or you can see water leaking – it may be a leak, the expansion vessel or the pressure relief valve. Book an engineer →
Source: Baxi Duo-tec Combi user guide (47-075-96) · Baxi technical note: error code E168 · What do error codes E28, E53, E133, E119 or E128 mean? · Why is my boiler pressure low?
-
E125
Water circulation fault (primary circuit).
What you can try
- Check the pressure is about 1–1.5 bar and top it up if it’s low.
- Otherwise there’s nothing to fix yourself.
When to call a Gas Safe engineer
If the pressure is fine and the code is still showing – the pump, valves or system water need checking. Book an engineer →
Source: Boiler error codes · Baxi Duo-tec Combi user guide (47-075-96) · Baxi 600 Combi user guide (47-077-28)
-
E128
Flame keeps going out (repeated flame loss).
What you can try
- Check your gas is on – does the hob or another gas appliance work?
- If you have a prepayment meter, make sure it has credit.
- In freezing weather, check the plastic condensate pipe outside isn’t frozen (see “Quick checks” above).
- Reset the boiler once.
When to call a Gas Safe engineer
If it won’t relight after one reset, or the code keeps coming back. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28) · What do error codes E28, E53, E133, E119 or E128 mean?
-
E129
Repeated flame loss during the boiler’s calibration.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
E130
Flue overheat – the flue temperature sensor has tripped.
What you can try
- Reset the boiler once (on Duo-tec models, turn the selector to Reset and hold for at least 5 seconds).
- Don’t keep resetting it if it comes straight back.
When to call a Gas Safe engineer
If the boiler doesn’t relight, or the code shows regularly. Book an engineer →
Source: Boiler error codes · Baxi Duo-tec Combi user guide (47-075-96) · Baxi 600 Combi user guide (47-077-28)
-
E131
Power was turned off during an E125 or E130 fault.
What you can try
- Reset the boiler once.
When to call a Gas Safe engineer
If it comes back – the cause of the original E125 or E130 needs finding. Book an engineer →
-
E133
Gas supply interrupted, ignition failed, or no flame detected. Shows as ‘E1’ then ‘33’ on some displays.
What you can try
- Check your gas is on – does the hob or another gas appliance work?
- If you have a prepayment meter, make sure it has credit.
- In freezing weather, check the plastic condensate pipe outside isn’t frozen (see “Quick checks” above).
- Reset the boiler once.
When to call a Gas Safe engineer
If it won’t relight after one reset, or the code keeps coming back. Book an engineer →
Source: Boiler error codes · Baxi Duo-tec Combi user guide (47-075-96) · Baxi 600 Combi user guide (47-077-28) · How to reset a Baxi boiler · What do error codes E28, E53, E133, E119 or E128 mean? · How to thaw a frozen condensate pipe
-
E134
Gas valve opened but no gas reached the burner.
What you can try
- Check your gas is on – does the hob or another gas appliance work?
- If you have a prepayment meter, make sure it has credit.
- In freezing weather, check the plastic condensate pipe outside isn’t frozen (see “Quick checks” above).
- Reset the boiler once.
When to call a Gas Safe engineer
If it won’t relight after one reset, or the code keeps coming back. Book an engineer →
Source: Boiler error codes
-
E135
Interruption of gas supply (internal error).
What you can try
- Check your gas is on – does the hob or another gas appliance work?
- If you have a prepayment meter, make sure it has credit.
- In freezing weather, check the plastic condensate pipe outside isn’t frozen (see “Quick checks” above).
- Reset the boiler once.
When to call a Gas Safe engineer
If it won’t relight after one reset, or the code keeps coming back. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E154
Flow and return temperature test failed.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E156
Low voltage – the boiler is getting less than 195V.
What you can try
- Make sure nothing else in the house has tripped or lost power.
- Write down the code.
When to call a Gas Safe engineer
If it keeps happening – the electrical supply to the boiler needs checking. Book an engineer →
-
E160
Fan or fan wiring fault.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi Duo-tec Combi user guide (47-075-96) · Baxi 600 Combi user guide (47-077-28)
-
E168
General lockout – often replaces an earlier code after a reset or a power cut, or points to an irregular power supply.
What you can try
- Tell your engineer about any other code you saw before E168 – it helps find the real fault.
- Reset the boiler once.
When to call a Gas Safe engineer
If it comes back after one reset. Book an engineer →
-
E270
Dry fire – circulation fault.
What you can try
- Check the pressure is about 1–1.5 bar and top it up if it’s low.
- Otherwise there’s nothing to fix yourself.
When to call a Gas Safe engineer
If the pressure is fine and the code is still showing – the pump, valves or system water need checking. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E317 / E162
Wrong electrical supply frequency.
What you can try
- Make sure nothing else in the house has tripped or lost power.
- Write down the code.
When to call a Gas Safe engineer
If it keeps happening – the electrical supply to the boiler needs checking. Book an engineer →
Source: Boiler error codes
-
E321 / E163
Hot water temperature sensor fault.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E384 / E164
False flame detected – the boiler sees a flame that shouldn’t be there.
What you can try
- Switch the boiler off and don’t keep resetting it.
When to call a Gas Safe engineer
Straight away. Book an engineer →
Source: Boiler error codes · Baxi 600 Combi user guide (47-077-28)
-
E385 / E165
Low supply voltage.
What you can try
- Make sure nothing else in the house has tripped or lost power.
- Write down the code.
When to call a Gas Safe engineer
If it keeps happening – the electrical supply to the boiler needs checking. Book an engineer →
Source: Boiler error codes
-
E430 / E166
Water pressure fault.
What you can try
- Look at the pressure gauge or display. If it reads below 1 bar, top it up to about 1–1.5 bar using the filling loop or filling link under the boiler, then close it again.
- Then reset the boiler if the code doesn’t clear on its own.
When to call a Gas Safe engineer
If you need to top up more than every few weeks, the pressure won’t hold, or you can see water leaking – it may be a leak, the expansion vessel or the pressure relief valve. Book an engineer →
Source: Boiler error codes
Codes like A.02.06, H.02.07, E.04.10
Baxi 200, 400, 600 & 800 Combi 2, 600 & 800 System 2, Assure 500. These are the codes homeowners see most – Baxi lists a few more technical ones on their own site.
-
A.02.06
Low water pressure in the heating.
What you can try
- Look at the pressure gauge or display. If it reads below 1 bar, top it up to about 1–1.5 bar using the filling loop or filling link under the boiler, then close it again.
- Then reset the boiler if the code doesn’t clear on its own.
When to call a Gas Safe engineer
If you need to top up more than every few weeks, the pressure won’t hold, or you can see water leaking – it may be a leak, the expansion vessel or the pressure relief valve. Book an engineer →
Source: Boiler error codes · Repressurising a boiler with a digital pressure gauge · Why is my boiler pressure low?
-
H.02.07
Low water pressure in the heating (permanent).
What you can try
- Look at the pressure gauge or display. If it reads below 1 bar, top it up to about 1–1.5 bar using the filling loop or filling link under the boiler, then close it again.
- Then reset the boiler if the code doesn’t clear on its own.
When to call a Gas Safe engineer
If you need to top up more than every few weeks, the pressure won’t hold, or you can see water leaking – it may be a leak, the expansion vessel or the pressure relief valve. Book an engineer →
Source: Boiler error codes · Repressurising a boiler with a digital pressure gauge · Why is my boiler pressure low?
-
E.02.39
Pressure didn’t reach the minimum after 6 minutes of automatic filling.
What you can try
- Check the gauge – if it’s still below 1 bar, try topping up with the filling link.
When to call a Gas Safe engineer
If you need to top up more than every few weeks, the pressure won’t hold, or you can see water leaking – it may be a leak, the expansion vessel or the pressure relief valve. Book an engineer →
Source: Boiler error codes
-
H.01.18 / E.01.17
No water circulation (temporary or permanent).
What you can try
- Check the pressure is about 1–1.5 bar and top it up if it’s low.
- Otherwise there’s nothing to fix yourself.
When to call a Gas Safe engineer
If the pressure is fine and the code is still showing – the pump, valves or system water need checking. Book an engineer →
Source: Boiler error codes
-
E.04.10
Burner failed to light after 4 attempts.
What you can try
- Check your gas is on – does the hob or another gas appliance work?
- If you have a prepayment meter, make sure it has credit.
- In freezing weather, check the plastic condensate pipe outside isn’t frozen (see “Quick checks” above).
- Reset the boiler once.
When to call a Gas Safe engineer
If it won’t relight after one reset, or the code keeps coming back. Book an engineer →
Source: Boiler error codes
-
E.04.12
Ignition failure (flame monitoring).
What you can try
- Check your gas is on – does the hob or another gas appliance work?
- If you have a prepayment meter, make sure it has credit.
- In freezing weather, check the plastic condensate pipe outside isn’t frozen (see “Quick checks” above).
- Reset the boiler once.
When to call a Gas Safe engineer
If it won’t relight after one reset, or the code keeps coming back. Book an engineer →
Source: Boiler error codes
-
H.03.02
Temporary flame loss.
What you can try
- Check your gas is on – does the hob or another gas appliance work?
- If you have a prepayment meter, make sure it has credit.
- In freezing weather, check the plastic condensate pipe outside isn’t frozen (see “Quick checks” above).
When to call a Gas Safe engineer
If it keeps happening. Book an engineer →
Source: Boiler error codes
-
E.01.04
Flame lost five times in 24 hours.
What you can try
- Check your gas is on – does the hob or another gas appliance work?
- If you have a prepayment meter, make sure it has credit.
- In freezing weather, check the plastic condensate pipe outside isn’t frozen (see “Quick checks” above).
- Reset the boiler once.
When to call a Gas Safe engineer
If it won’t relight after one reset, or the code keeps coming back. Book an engineer →
Source: Boiler error codes
-
E.04.13
Fan blocked or running too fast.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
E.04.08
Maximum safe temperature reached.
What you can try
- Don’t keep resetting it if it comes straight back.
- Reset the boiler once.
When to call a Gas Safe engineer
If the boiler doesn’t relight, or the code shows regularly – there may be a circulation problem (pump, air or sludge). Book an engineer →
Source: Boiler error codes
-
H.01.14
Maximum flow or return temperature reached (temporary).
What you can try
- Give it a few minutes – it should clear on its own once it cools.
When to call a Gas Safe engineer
If it keeps happening. Book an engineer →
Source: Boiler error codes
-
E.01.20
Maximum flue gas temperature reached.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
E.00.20 / E.00.21
Flue gas temperature sensor not connected or short-circuited.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
E.04.01 / E.04.02
Flow temperature sensor short-circuited or disconnected.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
E.00.04 / E.00.05
Return temperature sensor disconnected or short-circuited.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
H.00.42
Water pressure sensor open or faulty.
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
H.03.05
Power supply voltage too low.
What you can try
- Make sure nothing else in the house has tripped or lost power.
- Write down the code.
When to call a Gas Safe engineer
If it keeps happening – the electrical supply to the boiler needs checking. Book an engineer →
Source: Boiler error codes
-
H.00.81
Room unit (thermostat/controller) disconnected.
What you can try
- Check your room thermostat or controller has power – if it uses batteries, try new ones.
When to call a Gas Safe engineer
If it won’t reconnect. Book an engineer →
Source: Boiler error codes
-
H.01.00 / E.02.17
Communication failure between the gas valve and the boiler’s control board (temporary or permanent).
What you can try
- Nothing to fix yourself – this is a part inside the boiler.
- Write down the code and switch the boiler off if it keeps cutting out.
When to call a Gas Safe engineer
Straight away – this needs a Gas Safe engineer to test the part. Book an engineer →
Source: Boiler error codes
-
H.02.00
Reset in progress.
What you can try
- Nothing to do – wait a moment for the boiler to finish resetting.
When to call a Gas Safe engineer
If it stays on this message. Book an engineer →
Source: Boiler error codes
Can’t find your code?
Check you’ve typed it as shown on the display. If it’s not here – or it’s not a Baxi – give us a call on 07709 135134 or book an engineer.
Where this information comes from
Code meanings are taken from Baxi’s published error code list and Baxi user guides. Always check your own boiler’s user guide too.
- Baxi – Boiler error codes
- Baxi – What do error codes E28, E53, E133, E119 or E128 mean?
- Baxi – How to thaw a frozen condensate pipe
- Baxi – How to reset a Baxi boiler
- Baxi – Repressurising a boiler with a digital pressure gauge
- Baxi – Why is my boiler pressure low?
- Baxi Duo-tec Combi user guide (47-075-96)
- Baxi 600 Combi user guide (47-077-28)
- Baxi technical note: error code E168
Boiler still not working?
Gastech Services – Gas Safe registered boiler repairs in Morley, Leeds and Wakefield, any make.